logo
Product Range
Seven product lines provide you with ideal testing and analyzing solutions
Quality certification
Passed ISO9001:201 standard quality management system certification; BSCI, CE, FCC, rohs…
Manufacturing process
Exclusive patented technology, ERP management, high level of Quality Control;
Ingenuity concept
Adhering to the spirit if craftsmanship, Peakmeter has always focused on one thing since its establishment;
Guilin Huayi Peakmeter Technology Co., Ltd.
Auto / Manual Range Multimeter Clamp Meter With Analogue Bar Graph Display

Auto / Manual Range Multimeter Clamp Meter With Analogue Bar Graph Display

6000 Counts
Ture RMS
-20~1000℃
Auto And Manual Range Digital Clamp Meter Multimeter With Analogue Bar Graph Display Features of Digital Clamp Meter Multimeter Max. voltage between measurement terminal and ground: 1000V DC or 1000VAC Battery under-voltage indication and Automatic shutdown Select measurement function and range automatically Overload protection throughout the range Display: 6000 counts LCD display Continuity, VFD, NCV test Specifications Range Accuracy DC Voltage 6V/60V/600V/1000V ±(0.5%+5)
Details
Auto Range 1000A AC Current Measurement Digital AC Clamp Meters With NCV and Ture RMS

Auto Range 1000A AC Current Measurement Digital AC Clamp Meters With NCV and Ture RMS

2000Counts
Auto Range
1000A AC
Advanced AC Digital Clamp Meters With Non-Contact Voltage Detection,NCV and Ture RMS Features of AC Digital Clamp Meter AC Current Measurement AC & DC Voltage Measurement Resistance and buzzer measurement Low Battery Indication Over range Indication: “OL” or “-OL” Unit display: with function and quantity of electricity unit display Max and Min measurement NCV and VDF Specification Range Accuracy DC Voltage 2V/20V ±(0.8%+2) 200V/1000V ±(1.0%+2) AC Voltage 2V/20V ±(1.0%+5) 200V
Details
Auto And Manual Range Digital Clamp Meter Multimeter With Analogue Bar Graph Display

Auto And Manual Range Digital Clamp Meter Multimeter With Analogue Bar Graph Display

Ture RMS
6000 Counts
Dual Display
Auto And Manual Range Digital Clamp Meter Multimeter With Analogue Bar Graph Display Features of AC Digital Clamp Meter ​Select measurement function and range automatically Overload protection throughout the range Max voltage between measurement terminal and ground:1000V DC or 1000 AC ​Operating height : MAX. 2000m Automatic shutdown time: 10 minutes Unnit display: Function and electricity quantity unit display Specifications Range Accuracy DC Voltage 6V/60V/600V ±(0.5%+3) AC
Details
Auto Power Off Clamp Insulation Meter Low Battery Indication Overload Protection

Auto Power Off Clamp Insulation Meter Low Battery Indication Overload Protection

4000 Counts
Data Hold
1000V AC/DC
Digital Clamp Insulation Meter , Auto Power Off / Low Battery Indication English User Manual:https://drive.google.com/open?id=1VXkzYG_OgkAarTwjLhBSvjKgtSDzCkvD Features of Digital Clamp Meter Auto range indication Diode test indication Continuity indication Hold data indication Relative measurement indication Low battery indication DC & AC voltage measurement DC & AC current measurement Resistance measurement Capacitance measurement Specifications Range Accuracy DC Voltage
Details
Auto Range TRMS Digital Clamp Meter Solar Clamp Meter AC/DC 1000V Voltage 1000A Current

Auto Range TRMS Digital Clamp Meter Solar Clamp Meter AC/DC 1000V Voltage 1000A Current

6000 Counts
VFD Function
1000V AC/DC
AC/DC Digital Clamp Meter 1000A Current Solar Clamp Meter 1000V Voltage Auto Range True-RMS Peakmeter Photovoltaic System Solution:Peakmeter Photovoltaic System Solution.pdf Features of Solar Digital Clamp Meter Max. voltage between measurement terminal and ground: 1000V DC or 1000VAC Battery under-voltage indication and Automatic shutdown Low impedance measurement to make result more accurate Full range with overload protection NCV: When voltage > 90V AC, buzzer and light
Details
6000 Counts Hand - Held Mini Digital Clamp Multimeter With Auto Range And Data Hold

6000 Counts Hand - Held Mini Digital Clamp Multimeter With Auto Range And Data Hold

6000 Counts
Auto Range
0-6000Ω
6000 Counts Hand - Held Mini Digital Clamp Multimeter With Auto Range And Data Hold Features of Hand-held Mini Digital Clamp Meter Max display value: 6000 numbers Over range indication: “OL” or “-OL” Battery under-voltage indication Backlight and reading hold Auto shutdown Specifications Range Accuracy DC Voltage 0.5~600V ±(0.5%+3) AC Voltage 1.0~600V ±(0.8%+5) AC Current 6A/60A/200A ‘±(2.5%+8) Resistance 0~6kΩ ±(0.8%+3) Features Display 6000 counts Auto Range √ Continuity √
Details
Intelligent Digital Clamp Meter , Measuring LPF, Peak, Max, Continuity

Intelligent Digital Clamp Meter , Measuring LPF, Peak, Max, Continuity

Auto Range
6000 Counts
Dual Display
Intelligent Digital Clamp Meter , Measuring LPF, Peak, Max, Continuity English User Manual:https://drive.google.com/open?id=1gYgW3IYUkWBdeGbRaVC41Wbv6vWnoGEG Features of Intelligent Digital Clamp Meter Automatically select measurement function and range Overload protection for the whole measurement range Maximum display value: 6000 digits Automatic Power Off time: 10 minutes AC Current Measurement DC/AC Voltage Measurement Measure AC current and AC voltage at the same time
Details
AC/DC Digital CLamp Meter With Ammeter , Voltmeter ,Double Mold,Back Light,Ohmmeter Measurement

AC/DC Digital CLamp Meter With Ammeter , Voltmeter ,Double Mold,Back Light,Ohmmeter Measurement

6600 Counts
600A AC/DC
600V AC/DC
Digital CLamp Meter With Ammeter , Voltmeter ,Double Mold Diode Test Ohmmeter Measurement Features of AC/DC Digital Clamp Meter with Double Mold Auto rangeand manual range options are available. Overrange protection is providedfor all anges. Maximum voltage betwen terminals and earthground:600V DC or rms AC. Operating altitude:max.2000 meters (7000ft,) Display LCD. Maximum valuedisplay:6599 digits. Specifications Range Accuracy DC Voltage 660mV/6.6V/66V ±(0.8%+3) 400mV 4V/40V
Details
Intelligent Anti - Burning Digital Clamp Meter Multimeter For Electric Power Maintenance

Intelligent Anti - Burning Digital Clamp Meter Multimeter For Electric Power Maintenance

NCV
6000 Counts
Auto Range
Intelligent Anti - Burning Digital Clamp Meter Multimeter For Electric Power Maintenance English User Manual:https://drive.google.com/open?id=1n5HmWOP1rwjL-bACGOLj9LmwELG_xoZf Features of Digital Clamp Meter Automatically select measurement and range. Overload protection for the whole measurement range. Data hold function low power indication, and auto power off Maximum allowable voltage between the measuring terminal and the Earth:600V DC or 600V AC. Professional AC Voltage
Details
Auto Manual Range AC DC TRMS Digital Clamp Meter Multimeter Analogue Bar Graph

Auto Manual Range AC DC TRMS Digital Clamp Meter Multimeter Analogue Bar Graph

6000 Counts
NCV
1000V AC/DC
Auto Manual Range AC & DC Digital Clamp meter T-RMS Analogue Bar Graph Multimeter Features of TRMS Digital Clamp Meter Max. voltage between measurement terminal and ground: 1000V DC or 1000VAC Battery under-voltage indication and Automatic shutdown Select measurement function and range automatically Overload protection throughout the range Display: 6000 counts LCD display Continuity, VFD, NCV test Specifications Range Accuracy DC Voltage 6V/60V/600V/1000V ±(0.5%+5) AC Voltage
Details
1 2 3 4 5 6 7 8
Guilin Huayi Peakmeter Technology Co., Ltd.
Openness · Cooperation · Shared Benefits · Win-win Outcomes
Contact Us

Please check your E-mail!

Your message must be between 20-3,000 characters!